BONFIGLIOLI Active Cube Instructions d'exploitation Page 152

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 176
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 151
150 Application manual Positioning 04/08
5.5.3 Homing modes, only ref. signal and actual position
Operation modes 33 and 34: Homing to first encoder ref. signal
Home position is the first encoder ref. signal in negative (operation mode 33) or
positive (operation mode 34) direction.
34
33
Encoder
reference signal
Operation mode
35: Current position is home position
Current position is home position. Home offset (Parameter 1131) is taken over as
actual position value.
Actual position value
Home position
35
Note: Without encoder ref. signal, homing modes 1 to 14 as well as 33 and 34
are not possible.
Application manual Positioning 04/08150
Vue de la page 151
1 2 ... 147 148 149 150 151 152 153 154 155 156 157 ... 175 176

Commentaires sur ces manuels

Pas de commentaire